WaterEx's RO Membrane descalant as the name suggests is used for maintaining RO membranes from depositions. With the immense backup of our research and technical team the formulation of the product assists the system in maintaining the efficiency. Silica, slimes, oils and other organic components' depositions are descaled with the product. There are two categories of the product, one catering to lower pH membrane and the to higher pH membranes.
Product No: WEC-730H
When it comes to contaminants based on organic compounds, like oils, silica, slimes and films, formed due to RO/NF/UF membranes; it is suggested to use an alkaline based product for treatment and cleaning. WaterEx's High pH membrane cleaner is the best choice for such a scenario.
WaterEx's High membrane descalant comprises of various organic dispersants that assist to break the colloidal clay depositions. This way the process of cleaning becomes more efficient as now the biocides can penetrate through easily.
To create a solution of 2-5% volume/volume% of WaterEx's high pH membrane descalant, it must be diluted with DM or permeate water to make a proper solution. Let this solution circulate in the system for at least 2 to 4 hours inclusive of the soaking time duration of about 20 to 60 minutes. Thereon wash the entire equipment till the time an equal pH level is met. Read the cleaning manual for a stepwise procedure of the above process.
Note: Once you get the container having the solution, agitate it before use. If you sense foulants or turbidity before use, get the product replaced.
Some safety precautions that must always be followed are:
WaterEx's High pH Membrane Descalant must be stored in the very same container as provided by the seller.
Keep the containers in covered, closed, cool, dry place, thus away from heat, flame and direct sunlight.
WaterEx's high pH RO membrane descalant is available in 30 KG and 60 KG drums.
Product No: WEC-730L
WaterEx's low pH membrane descalant is a formulation that assists in treatment of RO / NF / UF membranes. The composition of the product is of carbonates and sulfates of calcium, barium, magnesium and strontium.
In the case of iron scales, metal oxide depositions, silicates and colloidal clay, WaterEx's low pH Membrane descalant proves to be useful and effective.
To create a solution of 2-5% voulme/volume% of WaterEx's low pH membrane descalant, it must be diluted with DM or RO spread through water.
Let this solution circulate in the system for at least 2 to 4 hours inclusive of the soaking time duration of about 20 to 60 minutes.
There on wash the entire equipment till the time an equal pH level is met.
Read the cleaning manual for a stepwise procedure of the above process.
Note: Once you get the container having the solution agitate it before use. If you sense foulants before use get the product replaced. In case of multi-pass systems, each pass must be cleaned for optimisation of the performance of the system over all.
In case of a major choked membrane a higher concentration of the solution is advisable. A concentration up to 10% volume/volume must be used after treating it with i.e. a high pH membrane descalant.
Some safety precautions that must always be followed are:
WaterEx's low pH Membrane Descalant must be stored in the very same container as provided by the seller.
Keep the containers in covered, closed, cool, dry place, thus away from heat, flame and direct sunlight.
WaterEx's low pH RO membrane descalant is available in 30 KG and 60 KG drums.